The neutral red uptake (NRU) assay provides a quantitative measurement of the number of viable cells. The test is based on the ability of living cells to take up and bind neutral red (NR), a dye which easily penetrates cell membranes via non-ionic diffusion and accumulates in the lysosomes. Dying

Last updated on: 21-02-2022 - 15:23

Contact: Roel Anthonissen
Organisation: Sciensano
Status: History of use, Published in peer reviewed journal
The in vitro Alkaline Comet Assay is a microgel electrophoresis technique which allows to measure DNA damage (single and double strand breaks, alkali labile sites, incomplete excision repair sites and cross links) cell by cell. Cells are mixed with 0.8% Low Melting Point Agarose which is spread as a

Last updated on: 21-02-2022 - 15:21

Contact: Roel Anthonissen
Organisation: Sciensano
Status: History of use, Published in peer reviewed journal
The Ames test is a short-term bacterial reverse gene mutation assay specifically designed to detect a wide range of chemical substances that can produce genetic damage that leads to permanent gene mutations. The test has been described in detail in OECD TG 471 and employs several histidine dependent

Last updated on: 21-02-2022 - 15:15

Contact: Roel Anthonissen
Organisation: Sciensano
Status: Published in peer reviewed journal, Validated by an external party (e.g. OECD, EURL ECVAM,…)
Alkaline comet assay (COM) and Micronucleus test (MN) are well-established cytogenetic tests that are used to detect both immediate damages i.e. DNA fragmentation, and permanent damage which results in micronuclei formation. These techniques are often applied separately or, sometimes, in combination

Last updated on: 18-02-2022 - 16:42

Contact: Ha Nguyen
Organisation: Université Libre de Bruxelles (ULB), Sciensano
Partners: University of Liège (ULiège)
Status: History of use, Internally validated
Isolation Femoral and tibial bones are isolated from 10-12 weeks old C57BL/6J mice. After cutting the bone's ends, the bone marrow is flushed out using a 23G syringe with PBS into a 50ml falcon tube. After centrifugation cells are re-suspended in FCS (0.5ml/mouse leg). Differentiation 0.5ml of the

Last updated on: 14-08-2020 - 15:26

Contact: Jerome Hendriks
Organisation: University of Hasselt (UHasselt)
Status: History of use, Internally validated, Published in peer reviewed journal
Characterization of Human Oligodendroglia derived-EV-rich in sHSPs (HOG-EV-sHSPs). Establish HSPB1/B8 stably expressing cell lines for the production of sHSPs rich-EV cell culture conditioned medium. Human Oligodendroglia cell lines (HOG) were stably transduced with pLenti-HSPBs gene constructs

Last updated on: 14-08-2020 - 15:22

Contact: Joy Irobi
Organisation: University of Hasselt (UHasselt)
Status: Still in development, Internally validated, Currently submitted for further validation by an external party (e.g. OECD, EURL ECVAM,…)
Peripheral blood mononuclear cells (PBMC) are isolated from the peripheral blood using Ficoll gradient centrifugation. The PBMC are then stained with fluorescently-labelled monoclonal antibodies directed against cell surface or intracellular proteins that can be used to identify specific immune cell

Last updated on: 03-03-2020 - 11:46

Contact: Cannot be disclosed
Organisation: University of Hasselt (UHasselt)
Status: Published in peer reviewed journal
Cell line which is commonly used to study biological processes in mouse macrophages. It is a macrophage-like cell line derived from BALB/c mice.

Last updated on: 25-02-2020 - 23:58

Contact: Jerome Hendriks
Organisation: University of Hasselt (UHasselt)
Status: History of use
TEM, NTA and western blot were used to characterize the purified inflammation‐associated EV subpopulations from TNF-α treated HUVEC based on their sedimentation speeds (10K and110K) and surface markers (CDs and ICAM-1). Protein arrays were used to discover the immunomodulatory content of

Last updated on: 14-11-2019 - 14:02

Organisation: University of Hasselt (UHasselt)
Status: Published in peer reviewed journal, Currently submitted for further validation by an external party (e.g. OECD, EURL ECVAM,…)