The main objective of this research project is to create the first full-thickness cornea-on-chip, which comprises a 3D construct with every cellular layer of the cornea. This construct is embedded in a microfluidic chip with two channels that are continuously perfused. The epithelial side of the

Last updated on: 27-07-2022 - 09:35

Contact: Joris Van Meenen
Organisation: University of Antwerp (UAntwerpen)
Status: Still in development
A battery of in vitro genotoxicity assays is currently used to detect agents with DNA damaging and carcinogenic potential. Although the sensitivity of this battery of genotoxicity assays is high, the specificity is low (“false positive hit”), especially with the mammalian cell-based assay, compared

Last updated on: 11-07-2022 - 15:51

Contact: Marc Audebert
Organisation: Institut national de la recherche agronomique (INRAE)
Status: History of use, Internally validated, Published in peer reviewed journal, Currently submitted for further validation by an external party (e.g. OECD, EURL ECVAM,…)
In view of safety of pregnant women, a promising in vitro zebrafish embryo developmental toxicity assay has been developed to test pharmaceutical and chemical compounds for their teratogenic potential. The protocol deals with exposing zebrafish embryos to a range of compound concentrations at 28°C

Last updated on: 06-01-2020 - 16:55

Organisation: University of Antwerp (UAntwerpen)
Status: Still in development, Published in peer reviewed journal